INsTaLLaTION
Ideal Logic Code Combi -
Installation and Servicing
FLUE OUTLET
18 FLUE ExTENsION DUCTs - F
or total flue lengths greater than 575mm
pack D Flue extension duct kit contents
Flue duct support
Flue support cutting aid
(shown folded up)
Wall plugs - 4 off
Extension duct & clamp
1.0m (39") long
No. 10 x2" wood screw - 4 off
nm8732
17 sETTINg ThE FLUE - sIDE
Wall thicknesses of 148 to 378mm
Notes.
a.
If using the extension ducts go to Frame 18.
b.
For shorter flue requirements use non telescopic B Pack.
1.
Measure and note wall thickness x. Refer to Frame 10.
2.
Measure distance from side of boiler to inside of wall and
add to wall thickness x=L. Refer to Frame 10.
3.
Add 115mm to dimension L and set telescopic flue length
as indicated in drawing.
4.
Using a 3.5mm drill bit, drill one hole in outer air duct
taking care not to pierce plastic inner flue.
5.
Fix to length using self tappers provided.
6.
Seal outer air duct using the tape provided.
nm8945
L + 115
Drill hole
Adhere sealing tape
Measurement to be
taken from this point
non TelesCoPiC Flue - Wall thickness of 115mm to 440mm
TelesCoPiC Flue - Wall thickness of 150mm to 375mm
Notes.
If using the extension ducts go to Frame 18.
1.
Measure and note side flue length L. Refer to Frame 10.
2.
Add 125mm to dimension L and, measuring from the ring,
cut the outer tube only.
3.
To ensure the tube is cut square, mark the flue all the way
around.
4.
Cut the inner tube to a length 20mm longer to aid
engagement, using the cutting aid provided
Measure from
this
RING
3G9675
206279-1.indd 20
06/01/2011 09:10:03