16
INsTaLLaTION
Ideal Logic Code Combi -
Installation and Servicing
FLUE OUTLET
FLUE KITs
pack B
- supplied as standard
pack B
- optional telescopic
pack D
- optional extension kit for side flue or rear flue outlet.
Concentric Flue Retaining Kit -
Optional Kit for mechanical fixing
of flue joints
Finishing Kit
- Supplied as an optional extra.
Refer to ‘Flue Extension Ducts’
IMpORTaNT.
The boiler MUST
be installed in a vertical position
Dimension x
- Wall thickness.
Dimension L
- Wall thickness plus boiler spacing.
Dimension s
- Optional stand-off Frame depth 45mm.
10 DETERMININg ThE FLUE LENgTh aND FLUE paCKs REqUIRED
Note.
MaxiMuM Flue lengThs:
26
- 9M (horizonTal Flue)
33
- 8M (horizonTal Flue)
38
- 6M (horizonTal Flue)
26, 33, 38
- 7.5M (rooF Flue)
26, 33, 38
- 5M PriMarY anD 17M seConDarY is a TYPiCal Max.
Flue lengTh. (
For alternative details refer to Powered Vertical Instructions)
90
o
Elbow KIt 60/100 (EquIValEnt FluE lEngth rEsIstancE = 1m)
45
o
Elbow KIt 60/100 (EquIValEnt FluE lEngth rEsIstancE = 0.6m)
mInImum horIzontal FluE lEngths - tElEscoPIc tErmInal = 350mm
(C
entre line of turret to outside of wall terminal)
- onE PIEcE tErmInal = 285mm
197mm 197mm
Wall Thickness X
Side flue length L
155 mm
155 + S = 200mm
206279-10256
sIDE FLUE
REaR FLUE
197mm 197mm
Wall Thickness X
Side flue length L
155 mm
155 + S = 200mm
206279-10256
continued . . . . .
206279-1.indd 16
06/01/2011 09:09:55