I-7088 and M-7088 User Manual, Rev: A1.2 7MH-026-A12
35
2.7. $AA3N
Description:
This command is used to read the maximum counter value for a
specific channel.
Syntax:
$AA3N[CHKSUM](CR)
$
Delimiter character
AA
The address of the module to be read (00 to FF)
3
The command to read the maximum counter value
N
The channel to be read, zero based
Response:
Valid Command:
!AA(Data)[CHKSUM](CR)
InValid Command:
?AA[CHKSUM](CR)
!
Delimiter character for a valid command
?
Delimiter character for an invalid command
(An invalid command is returned if the specified
channel is incorrect)
AA
The address of the responding module (00 to FF)
(Data)
8 hexadecimal digits (00000001 to FFFFFFFF)
representing the maximum counter value
There will be no response if the command syntax is incorrect, there
is a communication error, or there is no module with the specified