I-7088 and M-7088 User Manual, Rev: A1.2 7MH-026-A12
62
Examples:
Command:
$01C0D
Response:
!0150.0
Reads the duty cycle value for PWM channel 0 of module 01 and
returns a value of 50%.
Command:
$01C1D
Response:
!0133.3
Reads the duty cycle value for PWM channel 1 of module 01 and
returns a value of 33.3%.
Related Commands:
Section 2.21 $AACnD(Data)