CS-F620TR Programming Software Manual
(rev 1.0) -
Timers Programming Screen
63
Group
Row
Description
Default
Scan Delay
Timers
DTCS Scan
Delay
Enter from 0 to 5 seconds. This is the interval of time that
the radio will stay on the channel during scan to decode a
DTCS tone. If it cannot decode the proper tone in this
interval of time, scan will continue.
0.500
Scan Delay
Timers
Conv. Turn-
off Code
Enter from 0 to .6 seconds. Sets the duration of reverse
burst after a transmission is finished. Used to quiet
squelch tails.
0.180
Scan Delay
Timers
CD Scan
Delay
Enter from 0 to 5 seconds. This is the interval of time the
radio will spend on each system looking for activity.
.090
Scan Delay
Timers
LTR Scan
Delay
Enter from .5 to 5 seconds. This is the interval of time
between when the LTR signal stops and the radio
resumes scanning.
0.600
Scan Delay
Timers
PassPort Scan
Delay
Enter from 0 to 5 seconds. This is the interval of time
between when the PassPort signal stops and the radio
resumes scanning.
1.130
Timeout
Timers
(TOT)
Dispatch TX
TOT
Set to “OFF” (manually type the word in) or enter from 0
to 255 seconds. Setting this prevents the radio from
transmitting for a period longer than this timer.
30.000
Timeout
Timers
(TOT)
Phone TX
TOT
Set to “OFF” (manually type the word in) or enter from 0
to 255 seconds. Setting this prevents the radio from
transmitting on an interconnected system for a period
longer than this timer.
180.000
Timeout
Timers
(TOT)
Time Out Pre
Alert
Enter from .1 to 18 seconds. This sets the period of time,
before the Time Out Timer expires, that the radio sounds
a TOT warning beep.
5.000
Timeout
Timers
(TOT)
Time Out
Reset Time
Enter from .1 to 18 seconds. This sets the period of time,
after the Timeout Timer has expired, that the radio is
disabled from transmitting.
0.200
Timeout
Timers
(TOT)
Odometer
Write Interval
Enter from 10 to 180 seconds. This sets the time interval
in which the radio writes “bookkeeping” (runtime etc.)
information to its internal memory.
60.000
Display
Timers
Message
Hold Time
Enter from 0 to 5 seconds. Amount of time radio
messages are displayed on screen.
2.250
Display
Timers
Scan Interval
Enter from 0 to 5 seconds. Sets scrolling interval for
radio messages.
1.500
When done editing in this programming screen you can proceed to other programming
screens, save your programming parameters to a file or proceed to writing the
information to the radio (assuming that editing has been finished for all other required
programming screens also).