![Icom IC-F620 Programming Software Manual Download Page 35](http://html.mh-extra.com/html/icom/ic-f620/ic-f620_programming-software-manual_612653035.webp)
CS-F620TR Programming Software Manual
(rev 1.0) -
LTR Programming Screen
32
Group
Field
Description
Default
Suggested
Settings
TG
Dec. Pri.
TG
Select “Enable” or “Disable”. Select “Enable”
if you wish to force monitor the Primary Group
(the first group listed in the LTR
Talk Group
Setting
programming sub-screen). Note,
selecting “Enable” here will also turn the “CH”
field of the first row of the LTR
Talk Group
Setting
programming sub-screen red, indicating
forced monitor. If set to “Enable,” it does not
matter if the radio is in scan mode or not, or
whether CH 1 (primary group) is a scan
member or not, the Primary Group will still be
monitored.
TOT
Set to “OFF” (manually type the word in) or
enter from 0 to 255 seconds. Setting this
prevents the radio from transmitting for a
period longer than this timer.
OFF
Set as
needed.
Talk
Around
Select “None” or any of the Conventional or
LTR systems that appear in this list. This is the
system reverted to if the
Talk Around
key is
pressed. When “None” is selected here and the
Talk Around
key is pressed, LTR simplex
operation on the home channel is allowed.
None
(Blank)
Consult your
system
operator.
ATB Ring
Back
Select “Enable” or “Disable”. If a user attempts
to transmit and the system is busy, enabling
this will sound a ringing tone when the system
is ready to accept traffic again.
Enable
(Blank)
Set as
needed.
Scan
Scan
Enable
Select “Enable” or “Disable”. Selecting
“Enable” will allow this system to be scanned
when performing system scan. Selecting
“Disable” will prevent this system from being
scanned. Even if the User Edit field is set to
“Enable” the user will not be able to add this
system to the list of systems scanned (if
“Disable” is selected in this field).
Enable
(Blank)
Set as
needed.
Scan
Block
Mode
Select “Enable” or “Disable”. When enabled,
this will cause the radio to receive all groups in
a range between the talk groups listed in the
LTR
Talk Group Setting
programming sub-
screen (see page 36) under CH 2 and CH 3.
Note: Ensure that the group listed under CH 2
is numerically lower than the group in CH 3 or
this field will be marked with a
and will not
work. These groups will be scanned no matter
the setting of the Scan Member field in the
LTR
Talk Group Setting
programming sub-
screen. If you do not intend to use Block Mode
do not assign a
Scan Type
key.
Disable
(Blank)
Set as
needed.