19
CONTROL COMMAND
19-13
Remote control (CI-V) information (Continued)
•
Scope Sweep speed settings
Command : 27 1A
0 0 X X
00=FAST
01=MID
02=SLOW
Fixed
•
Scope VBW (Video Band Width) settings
Command : 27 1D
0 0 X X
00=Narrow
01=Wide
Fixed
•
Scope Fixed edge frequency settings
Command : 27 1E
q
0 X
X X
X
w
e
r
t
y
u
i
o
!0
!1
!2
X X X X X X X 0 0 X X X X X X X X 0 0
10 Hz
digit:
0–
9
1 Hz
digit:
0–
9
1 kHz
digit:
0–
9
100 Hz
digit:
0–
9
100 kHz
digit:
0–
9
10 kHz
digit:
0–
9
10 MHz
digit:
0–6
1 MHz
digit:
0–
9
1000 MHz
digit:
0 (fixed)
100 MHz
digit:
0 (fixed)
10 Hz
digit:
0–
9
1 Hz
digit:
0–
9
1 kHz
digit:
0–
9
100 Hz
digit:
0–
9
100 kHz
digit:
0–
9
10 kHz
digit:
0–
9
10 MHz
digit:
0–6
1 MHz
digit:
0–
9
1000 MHz
digit:
0 (fixed)
100 MHz
digit:
0 (fixed)
Frequency range
Lower edge
Higher edge
Edge number: 01–03
L
Entry of 100 Hz or smaller digits are ignored.
q
Selectable Frequency ranges
Data Frequency range (Hz)
01
0.03 – 1.60
02
1.60 – 2.00
03
2.00 – 6.00
04
6.00 – 8.00
05
8.00 – 11.00
06
11.00 – 15.00
07
15.00 – 20.00
08
20.00 – 22.00
09
22.00 – 26.00
10
26.00 – 30.00
11
30.00 – 45.00
12
45.00 – 60.00
13
60.00 – 74.80
w
Selectable Edge number: 01 = 1, 02 = 2, 03 = 3
Previous view