You
can
define
the
storage
unit
LUNs
as
either
protected
or
unprotected.
From
a
storage
unit
physical
configuration
view
point,
all
IBM
iSeries
volumes
are
RAID-5
or
RAID-10
volumes
and
are
protected
within
the
storage
unit.
When
you
create
the
IBM
iSeries
LUNs
by
using
the
IBM
TotalStorage
DS
Storage
Manager,
you
can
create
them
as
logically
protected
or
unprotected.
Table
5
shows
the
disk
capacity
for
the
protected
and
unprotected
models.
To
logically
unprotect
a
storage
LUN,
allow
the
iSeries
host
to
perform
remote
load
source
mirroring
to
that
device.
Because
the
load
source
is
mirrored
on
an
external
LUN,
the
storage
unit
can
copy
or
transfer
this
load
source
as
a
disaster
recovery
backup.
When
you
use
the
iSeries
tools
kit,
an
iSeries
host
in
a
remote
location,
using
a
copy
of
the
original
load
source,
can
recover
this
load
source
and
start
running
as
if
this
recovery
box
was
the
original
source
host.
Table
5.
Capacity
and
models
of
disk
volumes
for
IBM
iSeries
Size
Type
Protected
model
Unprotected
model
Release
support
8.5
GB
1750
A01
A81
Version
5
Release
2
or
later
17.5
GB
1750
A02
A82
Version
5
Release
2
or
later
35.1
GB
1750
A05
A85
Version
5
Release
2
or
later
70.5
GB
1750
A04
A84
Version
5
Release
2
or
later
141.1
GB
1750
A06
A86
Version
5
Release
3
or
later
282.2
GB
1750
A07
A87
Version
5
Release
3
or
later
Description........................:
Disk
unit
Type-Model.........................:
1750-A82
Status.............................:
Operational
Serial
number......................:
75-1409194
Part
number........................:
Resource
name......................:
DD143
licensed
machine
code.............:
FFFFFFFF
Level..............................:
PCI
bus............................:
System
bus.......................:
35
System
board.....................:
0
System
card......................:
32
Storage............................:
I/O
adapter......................:
6
I/O
bus..........................:
0
Controller.......................:
1
Device...........................:
1
Figure
34.
Example
of
the
display
for
the
auxiliary
storage
hardware
resource
detail
for
the
storage
unit
Chapter
7.
Attaching
to
an
IBM
iSeries
host
63
Summary of Contents for System storage DS6000 Series
Page 1: ...IBM TotalStorage DS6000 Host Systems Attachment Guide GC26 7680 03...
Page 2: ......
Page 3: ...IBM TotalStorage DS6000 Host Systems Attachment Guide GC26 7680 03...
Page 16: ...xiv DS6000 Host Systems Attachment Guide...
Page 28: ...xxvi DS6000 Host Systems Attachment Guide...
Page 30: ...xxviii DS6000 Host Systems Attachment Guide...
Page 50: ...20 DS6000 Host Systems Attachment Guide...
Page 84: ...54 DS6000 Host Systems Attachment Guide...
Page 88: ...58 DS6000 Host Systems Attachment Guide...
Page 164: ...134 DS6000 Host Systems Attachment Guide...
Page 170: ...140 DS6000 Host Systems Attachment Guide...
Page 174: ...144 DS6000 Host Systems Attachment Guide...
Page 192: ...162 DS6000 Host Systems Attachment Guide...
Page 212: ...182 DS6000 Host Systems Attachment Guide...
Page 226: ...196 DS6000 Host Systems Attachment Guide...
Page 240: ...210 DS6000 Host Systems Attachment Guide...
Page 248: ...218 DS6000 Host Systems Attachment Guide...
Page 250: ...220 DS6000 Host Systems Attachment Guide...
Page 256: ...Taiwan class A compliance statement VS07171L 226 DS6000 Host Systems Attachment Guide...
Page 297: ......
Page 298: ...Printed in USA GC26 7680 03...