Installing
the
KGPSA-
xx
adapter
card
in
an
OpenVMS
host
system
This
section
provides
the
steps
you
must
follow
to
install
the
KGPSA-
xx
adapter
card.
1.
Shut
down
the
Hewlett-Packard
AlphaServer
host
system.
2.
Use
the
procedures
that
are
provided
by
the
manufacturer
of
the
adapter
card
to
install
the
KGPSA-
xx
host
adapter.
3.
Restart
the
host
(nonclustered
configurations)
or
each
cluster
member
(clustered
configurations).
4.
Bring
each
host
system
to
a
halt
condition
at
the
console
level.
5.
Type
set
mode
diag
at
the
Hewlett-Packard
AlphaServer
console
to
place
the
console
in
diagnostic
mode.
Note:
This
step
is
only
for
certain
AlphaServer
models.
6.
Type
wwidmgr-show
adapter
to
confirm
that
you
installed
each
adapter
properly.
7.
If
necessary,
update
the
adapter
firmware.
Figure
25
shows
an
example
of
what
you
see
when
you
type
set
mode
diag
and
wwidmgr
-show
adapter
.
Figure
25
shows
the
worldwide
node
name
(WWNN).
You
also
need
the
worldwide
port
name
(WWPN)
to
configure
the
storage
unit
host
attachment.
To
determine
the
WWPN
for
the
KGPSA
adapters,
replace
the
}
2
}
in
the
WWNN
with
a
}
1
}
.
Setting
the
mode
for
the
KGPSA-
xx
host
adapter
in
an
OpenVMS
host
system
This
task
describes
setting
the
mode
for
the
KGPSA-
xx
host
adapter
for
an
HP
OpenVMS
host
system.
You
must
install
the
KGPSA-
xx
host
adapter
before
you
can
set
the
mode.
The
KGPSA-
xx
fibre-channel
adapter
card
must
be
set
to
FABRIC.
Use
the
wwidmgr
-show
adapter
console
command
to
see
the
setting
for
the
Cur.
Topo
and
Next
Topo
variables.
Figure
26
on
page
45
shows
example
output
from
the
wwidmgr
command.
1.
Type
#
shutdown
-h
now
to
shutdown
the
operating
system.
P00>>>
set
mode
diag
Console
is
in
diagnostic
mode
P00>>>
wwidmgr
-show
adapter
polling
for
units
on
kgpsa0,
slot
9,
bus
0,
hose0...
kgpsaa0.0.0.9.0
PGA0
WWN
2000-0000-c922-69bf
polling
for
units
on
kgpsa1,
slot
10,
bus
0,
hose0...
kgpsab0.0.0.10.0
PGB0
WWN
2000-0000-c921-df4b
item
adapter
WWN
Cur.
Topo
Next
Topo
[
0]
kgpsab0.0.0.10.0
2000-0000-c921-df4b
FABRIC
FABRIC
[
1]
kgpsaa0.0.0.9.0
2000-0000-c922-69bf
FABRIC
FABRIC
[9999]
All
of
the
above.
P00>>>
Figure
25.
Example
of
the
set
mode
diag
command
and
the
wwidmgr
-show
adapter
command
44
DS6000
Host
Systems
Attachment
Guide
Summary of Contents for System storage DS6000 Series
Page 1: ...IBM TotalStorage DS6000 Host Systems Attachment Guide GC26 7680 03...
Page 2: ......
Page 3: ...IBM TotalStorage DS6000 Host Systems Attachment Guide GC26 7680 03...
Page 16: ...xiv DS6000 Host Systems Attachment Guide...
Page 28: ...xxvi DS6000 Host Systems Attachment Guide...
Page 30: ...xxviii DS6000 Host Systems Attachment Guide...
Page 50: ...20 DS6000 Host Systems Attachment Guide...
Page 84: ...54 DS6000 Host Systems Attachment Guide...
Page 88: ...58 DS6000 Host Systems Attachment Guide...
Page 164: ...134 DS6000 Host Systems Attachment Guide...
Page 170: ...140 DS6000 Host Systems Attachment Guide...
Page 174: ...144 DS6000 Host Systems Attachment Guide...
Page 192: ...162 DS6000 Host Systems Attachment Guide...
Page 212: ...182 DS6000 Host Systems Attachment Guide...
Page 226: ...196 DS6000 Host Systems Attachment Guide...
Page 240: ...210 DS6000 Host Systems Attachment Guide...
Page 248: ...218 DS6000 Host Systems Attachment Guide...
Page 250: ...220 DS6000 Host Systems Attachment Guide...
Page 256: ...Taiwan class A compliance statement VS07171L 226 DS6000 Host Systems Attachment Guide...
Page 297: ......
Page 298: ...Printed in USA GC26 7680 03...