v
Multiple
OpenVMS
systems
can
access
the
same
storage
unit
adapter
port.
However,
you
must
define
each
system
for
that
specific
storage
unit
port
and
assign
at
least
one
storage
unit
volume.
v
To
re-enable
compatibility,
you
can
force
the
defined
OpenVMS
host
to
reestablish
connectivity
to
the
storage
unit
adapter
by
disabling
the
switch
port
it
is
connected
to,
and
then
enable
the
switch
port
again.
Troubleshooting
fibre-channel
attached
volumes
for
the
OpenVMS
host
system
This
section
contains
a
few
examples
of
issues
that
can
occur
with
your
OpenVMS
host
system
and
some
suggestions
to
correct
the
issues.
Problem
The
following
communication
problems
might
occur
when
you
attach
a
storage
unit
to
an
HP
AlphaServer
OpenVMS
host
system.
Investigation
If
the
system
hangs
during
boot
Your
system
might
be
attempting
to
access
a
host
adapter
port
that
is
not
configured
for
it.
To
correct
your
system,
check
to
ensure
that
the
following
items
are
true:
1.
The
fibre-channel
switch
is
enabled
to
ensure
zoning.
2.
The
zones
for
the
OpenVMS
host
are
connected
to
only
those
ports
that
are
correctly
configured
to
support
them.
3.
Other
fabric
zones
do
not
include
the
OpenVMS
host
adapters
by
mistake.
If
the
system
reaches
the
mount
verification
timeout
All
pending
and
future
I/O
requests
to
the
volume
fail.
You
have
to
dismount
and
remount
the
disk
before
you
can
access
it
again.
The
mount
verification
process
for
fibre
attached
volumes
might
not
complete
until
the
system
reaches
the
mount
verification
timeout.
This
can
be
caused
by
the
same
scenario
that
causes
the
system
to
hang
during
boot.
Verify
that
the
path
to
the
affected
volumes
is
available,
and
then
follow
the
above
list.
If
another
host
system
gains
access
to
a
storage
unit
host
adapter
port
that
is
dedicated
for
OpenVMS
The
port
will
have
its
compatibility
mode
disabled.
This
can
occur
when
the
fabric
switch
has
disabled
all
zoning.
After
you
reenable
zoning,
the
storage
unit
port
compatibility
remains
disabled.
Some
internal
storage
unit
processes
cause
a
momentary
loss
of
connectivity
to
volumes
with
activity
I/O.
OpenVMS
has
no
problems
when
the
storage
unit
adapter
port
is
in
compatibility
mode.
If
the
mode
is
disabled,
disk
I/O
could
fail
a
read
or
write
and
display
the
following
message:
-SYSTEM-F-TOOMANYRED,
too
many
redirects
Force
the
host
adapter
to
reestablish
connectivity
Forcing
the
OpenVMS
host
adapter
to
reestablish
fibre-channel
connectivity
with
the
storage
unit
adapter
port
will
enable
compatibility
mode.
You
can
force
the
connection
only
by
disconnecting
and
then
reconnecting
one
end
of
the
physical
fibre-channel
cable
between
the
host
and
the
affected
52
DS6000
Host
Systems
Attachment
Guide
Summary of Contents for System storage DS6000 Series
Page 1: ...IBM TotalStorage DS6000 Host Systems Attachment Guide GC26 7680 03...
Page 2: ......
Page 3: ...IBM TotalStorage DS6000 Host Systems Attachment Guide GC26 7680 03...
Page 16: ...xiv DS6000 Host Systems Attachment Guide...
Page 28: ...xxvi DS6000 Host Systems Attachment Guide...
Page 30: ...xxviii DS6000 Host Systems Attachment Guide...
Page 50: ...20 DS6000 Host Systems Attachment Guide...
Page 84: ...54 DS6000 Host Systems Attachment Guide...
Page 88: ...58 DS6000 Host Systems Attachment Guide...
Page 164: ...134 DS6000 Host Systems Attachment Guide...
Page 170: ...140 DS6000 Host Systems Attachment Guide...
Page 174: ...144 DS6000 Host Systems Attachment Guide...
Page 192: ...162 DS6000 Host Systems Attachment Guide...
Page 212: ...182 DS6000 Host Systems Attachment Guide...
Page 226: ...196 DS6000 Host Systems Attachment Guide...
Page 240: ...210 DS6000 Host Systems Attachment Guide...
Page 248: ...218 DS6000 Host Systems Attachment Guide...
Page 250: ...220 DS6000 Host Systems Attachment Guide...
Page 256: ...Taiwan class A compliance statement VS07171L 226 DS6000 Host Systems Attachment Guide...
Page 297: ......
Page 298: ...Printed in USA GC26 7680 03...