This is the maximum time (in minutes) the service processor should wait for a
heartbeat from the operating system before timeout.
v
Surveillance delay
This is the length of time (in minutes) for the service processor to wait from when the
operating system is started to when the first heartbeat is expected.
Surveillance takes effect immediately after the parameters are set from the service
processor menus.
If operating system surveillance is enabled (and system firmware has passed control to
the operating system), and the service processor does not detect any heartbeats from
the operating system, the service processor assumes the system is hung. The machine
is left powered on and the service processor enters standby phase, displaying the
operating system surveillance failure code on the operator panel. If Call-out is enabled,
the service processor calls to report the failure.
Call Out
The service processor can call out when it detects one of the following conditions:
v
System firmware surveillance failure
v
Operating system surveillance failure (if supported by the operating system)
v
Critical environmental failures
v
Restarts
To enable the call-out feature, do the following:
1. Have a modem connected to serial port 1 or 2
2. Set up the following using the service processor Menus or Diagnostic Service Aids:
v
Enable call out for the serial port where the modem is connected.
v
Set up serial port line speed.
v
Enter the modem configuration filename.
v
Set up site-specific parameters (such as phone numbers for call out and call out
policy).
v
To call out before restart, set Call-Out before restart to ENABLED from the
Reboot/Restart Policy Setup menu.
Note: Some modems, such as IBM 7857-017, are not designed for the paging function.
Although they can be used for paging, they return an error message when they
do not get the expected response from another modem. Therefore, even though
the paging was successful, the error message causes the service processor to
retry, continuing to place pager calls for the number of retries specified in the
Call-Out policy Setup Menu. These retries result in redundant pages.
66
44P Series Model 170 User’s Guide
Summary of Contents for RS/6000 44P Series 270
Page 2: ......
Page 3: ...RS 6000 44P Series Model 170 User s Guide User s Guide SA38 0559 01 IBM...
Page 12: ...x 44P Series Model 170 User s Guide...
Page 16: ...xiv 44P Series Model 170 User s Guide...
Page 90: ...72 44P Series Model 170 User s Guide...
Page 124: ...106 44P Series Model 170 User s Guide...
Page 162: ...144 44P Series Model 170 User s Guide...
Page 166: ...148 44P Series Model 170 User s Guide...
Page 180: ...162 44P Series Model 170 User s Guide...
Page 182: ...164 44P Series Model 170 User s Guide...
Page 184: ...166 44P Series Model 170 User s Guide...
Page 208: ...190 44P Series Model 170 User s Guide...
Page 215: ......