Note: The term
POST indicator refers to the Icons (graphic display) or device
mnemonics (ASCII terminal) that are displayed while the POST is
executing.
6. Enter any requested password.
7. Follow any instructions to select a console.
8. After the diagnostic controller loads, DIAGNOSTIC OPERATING INSTRUCTIONS
appear on the console display.
9. Follow the displayed instructions to check out the desired resources.
10. When testing is complete, use the F3 key to return to the DIAGNOSTIC
OPERATING INSTRUCTIONS.
11. Press the F3 key (from a defined terminal) or press 99 (for an undefined terminal)
to shut down the diagnostics before turning off the system unit.
Note: Pressing the F3 key (from a defined terminal) produces a Confirm Exit menu
containing two options:
v
Continue with the shutdown by pressing F3.
v
Return to diagnostics by pressing Enter.
For undefined terminals, pressing 99 produces a menu containing two options:
v
Continue with the shutdown by pressing 99, then Enter
v
Return to diagnostics by pressing Enter.
Concurrent Mode
Concurrent mode provides a way to run Online diagnostics on some of the system
resources while the system is running normal activity.
Because the system is running in normal operation, some of the resources cannot be
tested. The following resources cannot be tested in concurrent mode:
v
SCSI adapters connected to paging devices
v
Disk drive used for paging
v
Any graphics-related device if running X, CDE, or windowing environment.
v
Memory
v
Processor
Three levels of testing are available in concurrent mode:
v
The share-test level tests a resource while the resource is being shared by
programs running in the normal operation. This testing is mostly limited to normal
commands that test for the presence of a device or adapter.
v
The sub-test level tests a portion of a resource while the remaining part of the
resource is being used in normal operation. For example, this test could test one port
of a multiport device while the other ports are being used in normal operation.
v
The full-test level requires the device not be assigned to or used by any other
operation. This level of testing on a disk drive might require the use of the varyoff
command. The diagnostics display menus allow you to vary off the needed resource.
110
44P Series Model 170 User’s Guide
Summary of Contents for RS/6000 44P Series 270
Page 2: ......
Page 3: ...RS 6000 44P Series Model 170 User s Guide User s Guide SA38 0559 01 IBM...
Page 12: ...x 44P Series Model 170 User s Guide...
Page 16: ...xiv 44P Series Model 170 User s Guide...
Page 90: ...72 44P Series Model 170 User s Guide...
Page 124: ...106 44P Series Model 170 User s Guide...
Page 162: ...144 44P Series Model 170 User s Guide...
Page 166: ...148 44P Series Model 170 User s Guide...
Page 180: ...162 44P Series Model 170 User s Guide...
Page 182: ...164 44P Series Model 170 User s Guide...
Page 184: ...166 44P Series Model 170 User s Guide...
Page 208: ...190 44P Series Model 170 User s Guide...
Page 215: ......