Diagnostic Error Code
FRU/Action
001-027-XXX
System Configuration/Setup error
1.
Run Setup
2.
Flash the system
3.
System board
001-032-XXX
System Device Controller failure
1.
System board
001-034-XXX
System Device Buffer Allocation
failure
1.
Reboot the system
2.
Flash the system
3.
Run memory test
4.
System board
001-035-XXX
System Device Reset condition
detected
1.
System board
001-036-XXX
System Register error
1.
System board
001-038-XXX
System Extension failure
1.
Adapter card
2.
System board
001-039-XXX
System DMI data structure error
1.
Flash the system
2.
System board
001-040-XXX
System IRQ failure
1.
Power-off/on system and re-test
2.
System board
001-041-XXX
System DMA failure
1.
Power-off/on system and re-test
2.
System board
001-195-XXX
System Test aborted by user
1.
Information
2.
Re-start the test, if necessary
001-196-XXX
System test halt, error threshold
exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
001-197-XXX
System test warning
1.
Make sure the component that is called out is
connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning statement
4.
Component under test
001-198-XXX
System test aborted
1.
If a component is called out, make sure it is
connected and/or enabled
2.
Flash the system and re-test
3.
Go to the
″
Undetermined problems
″
section
Chapter 1. IBM PC Enhanced Diagnostics error codes
3
Summary of Contents for NetVista 6058
Page 2: ......
Page 7: ...About this manual v...
Page 159: ...3 Lift out the power supply Chapter 3 Types 6058 6059 6269 6578 6579 145...
Page 187: ...Parts Types 6058 6059 6269 6578 6579 Chapter 3 Types 6058 6059 6269 6578 6579 173...
Page 213: ...Chapter 4 Related Service Information 199...
Page 215: ...Chapter 4 Related Service Information 201...
Page 217: ...Chapter 4 Related Service Information 203...
Page 235: ...Chapter 4 Related Service Information 221...
Page 247: ......
Page 248: ...Part Number 06P1504 1P P N 06P1504...