Diagnostic Error Code
FRU/Action
018-0XX-XXX
PCI Card Failure
1.
Riser card, if installed
2.
System board
018-195-XXX
PCI Card Test aborted by user
1.
PCI card
2.
Information
3.
Re-start the test, if necessary
018-196-XXX
PCI Card test halt, error threshold
exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
018-197-XXX
PCI Card test warning
1.
Make sure the component that is called out is
connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning statement
4.
Component under test
018-198-XXX
PCI Card test aborted
1.
Make sure the component that is called out is
connected and/or enabled
2.
Flash the system and re-test
3.
Go to the
″
Undetermined problems
″
section
018-199-XXX
PCI Card test failed, cause
unknown
1.
Go to the
″
Undetermined problems
″
section
2.
Flash the system and re-test
3.
Replace component under function test
018-250-XXX
PCI Card Services error
1.
PCI card
2.
Riser card, if installed
3.
System board
020-000-XXX
PCI Interface Test Passed
1.
No action
020-0XX-XXX
PCI Interface error
1.
PCI card
2.
Riser card, if installed
3.
System board
020-195-XXX
PCI Test aborted by user
1.
Information
2.
Re-start the test, if necessary
020-196-XXX
PCI test halt, error threshold
exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
Chapter 1. IBM PC Enhanced Diagnostics error codes
11
Summary of Contents for NetVista 6058
Page 2: ......
Page 7: ...About this manual v...
Page 159: ...3 Lift out the power supply Chapter 3 Types 6058 6059 6269 6578 6579 145...
Page 187: ...Parts Types 6058 6059 6269 6578 6579 Chapter 3 Types 6058 6059 6269 6578 6579 173...
Page 213: ...Chapter 4 Related Service Information 199...
Page 215: ...Chapter 4 Related Service Information 201...
Page 217: ...Chapter 4 Related Service Information 203...
Page 235: ...Chapter 4 Related Service Information 221...
Page 247: ......
Page 248: ...Part Number 06P1504 1P P N 06P1504...