Diagnostic Error Code
FRU/Action
175-199-XXX
Thermal Sensor(s) test failed,
cause unknown
1.
Go to the
″
Undetermined problems
″
section
2.
Flash the system and re-test
3.
Replace component under function test
175-250-XXX
175-251-XXX
Thermal Sensor(s) limit error
1.
Check fans
2.
Check Power supply
3.
Microprocessor
4.
System board
185-000-XXX
Asset Security Test Passed
1.
No action
185-XXX-XXX
Asset Security failure
1.
Flash system
2.
System board
185-278-XXX
Asset Security Chassis Intrusion
1.
Assure Asset Security Enabled
2.
C2 Cover Switch
3.
System board
201-000-XXX
System Memory Test Passed
1.
No action
201-XXX-XXX
System Memory error
1.
Replace the memory module called out by the
test
2.
System board
202-000-XXX
System Cache Test Passed
1.
No action
202-XXX-XXX
System Cache error
1.
Cache, if removable
2.
System board
3.
Microprocessor
206-000-XXX
Diskette Drive Test Passed
1.
No action
206-XXX-XXX
Diskette Drive error
1.
Diskette Drive Cable
2.
Check power supply voltages
3.
Diskette drive
4.
System board
215-000-XXX
CD-ROM Drive Test Passed
1.
No action
215-XXX-XXX
CD-ROM Drive error
1.
CD-ROM Drive Cable
2.
Check power supply voltages
3.
CD-ROM drive
4.
System board
217-000-XXX
Hard Disk Drive Test Passed
1.
No action
Chapter 1. IBM PC Enhanced Diagnostics error codes
19
Summary of Contents for NetVista 6058
Page 2: ......
Page 7: ...About this manual v...
Page 159: ...3 Lift out the power supply Chapter 3 Types 6058 6059 6269 6578 6579 145...
Page 187: ...Parts Types 6058 6059 6269 6578 6579 Chapter 3 Types 6058 6059 6269 6578 6579 173...
Page 213: ...Chapter 4 Related Service Information 199...
Page 215: ...Chapter 4 Related Service Information 201...
Page 217: ...Chapter 4 Related Service Information 203...
Page 235: ...Chapter 4 Related Service Information 221...
Page 247: ......
Page 248: ...Part Number 06P1504 1P P N 06P1504...