If the printer self-test does not run correctly, the problem is in the printer.
Refer to the printer service manual.
If the printer self-test runs correctly, install a wrap plug in the parallel port
and run the diagnostic tests to determine which FRU failed.
If the diagnostic tests (with the wrap plug installed) do not detect a failure,
replace the printer cable. If that does not correct the problem, replace the
system board or adapter connected to the printer cable.
Power supply
If the power-on indicator is not on, the power supply fan is not running, or
the computer will not power-off, use the following procedures.
Check/Verify
FRU/Action
Verify that the voltage-selector switch is set for the
correct voltage.
Correct the voltage-selector switch setting
Check the following for proper installation.
v
Power Cord
v
On/Off Switch connector
v
On/Off Switch Power Supply connector
v
System Board Power Supply connectors
v
Microprocessor(s) connection
Reseat
Check the power-on switch for continuity.
Power Cord
Check the power-on switch for continuity.
Power-on Switch
If the above are correct, check the following voltages.
108
Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,
6649
Summary of Contents for NetVista 6058
Page 2: ......
Page 7: ...About this manual v...
Page 159: ...3 Lift out the power supply Chapter 3 Types 6058 6059 6269 6578 6579 145...
Page 187: ...Parts Types 6058 6059 6269 6578 6579 Chapter 3 Types 6058 6059 6269 6578 6579 173...
Page 213: ...Chapter 4 Related Service Information 199...
Page 215: ...Chapter 4 Related Service Information 201...
Page 217: ...Chapter 4 Related Service Information 203...
Page 235: ...Chapter 4 Related Service Information 221...
Page 247: ......
Page 248: ...Part Number 06P1504 1P P N 06P1504...