Diagnostic Error Code
FRU/Action
020-197-XXX
PCI test warning
1.
Make sure the component that is called out is
connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning statement
4.
Component under test
020-198-XXX
PCI test aborted
1.
If a component is called out, make sure it is
connected and/or enabled
2.
Flash the system and re-test
3.
Go to the
″
Undetermined problems
″
section
020-199-XXX
PCI test failed, cause unknown
1.
Go to the
″
Undetermined problems
″
section
2.
Flash the system and re-test
3.
Replace component under function test
020-262-XXX
PCI system error
1.
PCI card
2.
Riser card, if installed
3.
System board
025-000-XXX
IDE interface Test Passed
1.
No action
025-00X-XXX
025-01X-XXX
IDE interface failure
1.
IDE signal cable
2.
Check power supply
3.
IDE device
4.
System board
025-027-XXX
IDE interface Configuration/Setup
error
1.
IDE signal cable
2.
Flash the system
3.
IDE device
4.
System board
025-02X-XXX
025-03X-XXX
025-04X-XXX
IDE Interface failure
1.
IDE signal cable
2.
Check power supply
3.
IDE device
4.
System board
025-195-XXX
IDE interface Test aborted by user
1.
Information
2.
Re-start the test, if necessary
025-196-XXX
IDE interface test halt, error
threshold exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
12
Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,
6649
Summary of Contents for NetVista 6058
Page 2: ......
Page 7: ...About this manual v...
Page 159: ...3 Lift out the power supply Chapter 3 Types 6058 6059 6269 6578 6579 145...
Page 187: ...Parts Types 6058 6059 6269 6578 6579 Chapter 3 Types 6058 6059 6269 6578 6579 173...
Page 213: ...Chapter 4 Related Service Information 199...
Page 215: ...Chapter 4 Related Service Information 201...
Page 217: ...Chapter 4 Related Service Information 203...
Page 235: ...Chapter 4 Related Service Information 221...
Page 247: ......
Page 248: ...Part Number 06P1504 1P P N 06P1504...