POST Error Code
FRU/Action
107X
Check SCSI terminator installation
1.
Check SCSI terminator installation
2.
SCSI Cable
3.
SCSI Terminator
4.
SCSI Device
5.
SCSI Adapter
1101
Serial connector error, possible system board
failure
1.
Run Enhanced Diagnostics
1101, 1102, 1106, 1108, 1109
1.
System Board
2.
Any Serial Device
1107
1.
Communications Cable
2.
System Board
1102
Card selected feedback error
1.
Run Enhanced Diagnostics
1103
Port fails register check
1.
Run Enhanced Diagnostics
2.
System Board
1106
Serial option cannot be turned off
1.
Run Enhanced Diagnostics
2.
System Board
1107
1.
Serial Device Cable
2.
System Board
1110
Register test failed
1.
Run Enhanced Diagnostics
2.
System Board
1116
Interrupt error
1.
Run Enhanced Diagnostics
1117
Failed baud rate test
1.
Run Enhanced Diagnostics
1162
Serial port configuration error
1.
Run Configuration
2.
Serial Adapter
(if installed)
3.
System Board
11XX
Not listed above
1.
System Board
1201
1.
System Board
2.
Any Serial Device
1202, 1206, 1208, 1209, 12XX
1.
Dual Async Adapter/A
2.
System Board
3.
Any Serial Device
Chapter 2. Types 6568/6569/6648/6649
77
Summary of Contents for NetVista 6058
Page 2: ......
Page 7: ...About this manual v...
Page 159: ...3 Lift out the power supply Chapter 3 Types 6058 6059 6269 6578 6579 145...
Page 187: ...Parts Types 6058 6059 6269 6578 6579 Chapter 3 Types 6058 6059 6269 6578 6579 173...
Page 213: ...Chapter 4 Related Service Information 199...
Page 215: ...Chapter 4 Related Service Information 201...
Page 217: ...Chapter 4 Related Service Information 203...
Page 235: ...Chapter 4 Related Service Information 221...
Page 247: ......
Page 248: ...Part Number 06P1504 1P P N 06P1504...