POST Error Code
FRU/Action
1780
(Disk Drive 0)
1781
(Disk Drive 1)
1782
(Disk
Drive 2)
1783
(Disk Drive 3)
1.
See “Power supply” on page 108
2.
Hard Disk Drive
3.
System Board
4.
Hard Disk Cable
5.
Power Supply
180X, 188X
PCI configuration or resource error
1.
Run Setup and verify PCI/ISA configuration
settings.
2.
If necessary, set ISA adapters to
Not available
to
allow PCI adapters to properly configure.
3.
Remove any suspect ISA adapters.
4.
Rerun diagnostics.
5.
PCI Adapter
1962
Boot sequence error
1.
Possible hard disk drive problem; see “Hard
disk drive boot error” on page 123.
209X
1.
Diskette Drive
2.
Diskette Cable
20XX
Not listed above
1.
BSC Adapter
21XX
1.
SCSI Device
2.
16-bit AT Fast SCSU adapter
3.
Alternate BSC adapter
2401, 2402
If screen colors change
1.
Display
2401, 2402
If screen colors are OK
1.
System Board
2.
Display
2409
1.
Display
2410
1.
System Board
2.
Display
2462
Video memory configuration error
1.
Check cable connections
2.
Run Setup and verify video configuration
settings
3.
Video Memory Modules
4.
Video Adapter (if installed)
5.
System Board
4611, 4630
1.
Multiport/2 Interface Board
2.
Multiport/2 Adapter
Chapter 3. Types 6058/6059/6269/6578/6579
159
Summary of Contents for NetVista 6058
Page 2: ......
Page 7: ...About this manual v...
Page 159: ...3 Lift out the power supply Chapter 3 Types 6058 6059 6269 6578 6579 145...
Page 187: ...Parts Types 6058 6059 6269 6578 6579 Chapter 3 Types 6058 6059 6269 6578 6579 173...
Page 213: ...Chapter 4 Related Service Information 199...
Page 215: ...Chapter 4 Related Service Information 201...
Page 217: ...Chapter 4 Related Service Information 203...
Page 235: ...Chapter 4 Related Service Information 221...
Page 247: ......
Page 248: ...Part Number 06P1504 1P P N 06P1504...