Chapter 1. IBM PC Enhanced Diagnostics error codes
Refer to the following Diagnostic Error Codes when using the IBM PC
Enhanced Diagnostics test. See the
″
Diagnostic and test information
″
section
for the specific model for information about the IBM PC Enhanced
Diagnostics program.
In the following index,
X
can represent any number.
Diagnostic Error Code
FRU/Action
000-000-XXX
BIOS Test Passed
1.
No action
000-002-XXX
BIOS Timeout
1.
Flash the system
2.
System board
000-024-XXX
BIOS Addressing test failure
1.
Flash the system
2.
System board
000-025-XXX
BIOS Checksum Value error
1.
Flash the system
2.
Boot block
3.
System board
000-026-XXX
FLASH data error
1.
Flash the system
2.
Boot block
3.
System board
000-027-XXX
BIOS Configuration/Setup error
1.
Run Setup
2.
Flash the system
3.
Boot block
4.
System board
000-034-XXX
BIOS Buffer Allocation failure
1.
Reboot the system
2.
Flash the system
3.
Run memory test
4.
System board
000-035-XXX
BIOS Reset Condition detected
1.
Flash the system
2.
System board
000-036-XXX
BIOS Register error
1.
Flash the system
2.
Boot block
3.
System board
© Copyright IBM Corp. 2000
1
Summary of Contents for NetVista 6058
Page 2: ......
Page 7: ...About this manual v...
Page 159: ...3 Lift out the power supply Chapter 3 Types 6058 6059 6269 6578 6579 145...
Page 187: ...Parts Types 6058 6059 6269 6578 6579 Chapter 3 Types 6058 6059 6269 6578 6579 173...
Page 213: ...Chapter 4 Related Service Information 199...
Page 215: ...Chapter 4 Related Service Information 201...
Page 217: ...Chapter 4 Related Service Information 203...
Page 235: ...Chapter 4 Related Service Information 221...
Page 247: ......
Page 248: ...Part Number 06P1504 1P P N 06P1504...