010 (continued)
– Go to Step 013
011
– The module has an internal failure. It must be replaced. Go to Chapter 4, “FRU Exchange”
on page 4-1.
012
– Go to Step 018 on page 2-62.
013
– Browse the error-log and look for the following messages:
47ð98 1ð|ð9 ð9:ðð:1ð atmcshwi.c-2ð59
E CS
Hard minor ð5_2ð32_CS Unexpected Return
Code.
Missing GRC response to CONFIRM blade reg CF=ðx26 IS=ðx1ðð
ðððA6 DR=ðxð EC=ðx4E3A7 slot_id=17
47ð99 1ð|ð9 ð9:ðð:1ð atmc5hwg.c-357
E C5
Soft MAJOR ð5_6ðð1_C5 Unex
pected Return Code.
4x155 Mbps, cannot set framer register RSOPBIP8MSB to ðx11
(s=2 p=ð)
471ðð 1ð|ð9 ð9:ðð:1ð atmc5ctg.c-235
E C5
Soft MAJOR ð5_6ðð1_C5 Unex
pected Return Code.
4x155 Mbps, cannot trig B1ECT registers transfert (s=17 p=2)
471ð1 1ð|ð9 ð9:ðð:1ð atmc5ctg.c-391
E C5
Soft MAJOR ð5_6ðð1_C5 Unex
pected Return Code.
4x155 Mbps, cannot treat B1 counter (s=17 p=2)
471ð2 1ð|ð9 ð9:ðð:1ð atmcshwi.c-2ð59
E CS
Hard minor ð5_2ð32_CS Unex
pected Return Code.
Missing GRC response to CONFIRM blade reg CF=ðx26 IS=ðx1ðð
ðð1A6 DR=ðxð EC=ðx4E3A7 slot_id=17
471ð3 1ð|ð9 ð9:ðð:1ð atmc5hwg.c-314
E C5
Soft MAJOR ð5_6ðð1_C5 Unex
pected Return Code.
4x155 Mbps, cannot get framer register RSOPBIP8MSB (s=17 p=4)
471ð4 1ð|ð9 ð9:ðð:1ð atmc5ctg.c-246
E C5
Soft MAJOR ð5_6ðð1_C5 Unex
pected Return Code.
4x155 Mbps, cannot get B1ECT MSB register (s=17 p=4)
471ð5 1ð|ð9 ð9:ðð:1ð atmc5ctg.c-391
E C5
Soft MAJOR ð5_6ðð1_C5 Unex
pected Return Code.
4x155 Mbps, cannot treat B1 counter (s=17 p=4)
471ð6 1ð|ð9 ð9:ðð:15 atmcspol.c-329
E CS
Soft minor ð5_2ð43_CS Poll
response missing.
Cause slot 17 (no_resp=1), poll timer is now 3ððð ms (was 2ððð or 25ðð)
471ð7 1ð|ð9 ð9:ðð:2ð atmcspol.c-329
E CS
Soft minor ð5_2ð43_CS Poll
response missing.
Cause slot 17 (no_resp=1), poll timer is now 3ððð ms (was 2ððð or 25ðð)
Did you receive the previous messages?
Yes No
014
– Go to Step 016 on page 2-62.
015
– The probable cause is a port/module congestion, due to CBR/reserved bandwidth traffic exceeding
physical limitations of the module (User/Configuration error). Complete the problem determination by
checking active connections on this module. Enter the
show signalling cross_connections port
<slot.n> command for each port, and check for CBR connections suc as:
Chapter 2.
MAPS
2-61
Summary of Contents for 8265 Nways ATM Switch
Page 1: ...8265 Nways ATM Switch IBM Problem Determination and Service Guide SY33 2128 00...
Page 2: ......
Page 3: ...8265 Nways ATM Switch IBM Problem Determination and Service Guide SY33 2128 00...
Page 8: ...vi 8265 PD and SG...
Page 10: ...viii 8265 PD and SG...
Page 11: ...Tables 3 1 Wraps available on WAN Modules 3 9 Copyright IBM Corp 1998 ix...
Page 12: ...x 8265 PD and SG...
Page 18: ...xvi 8265 PD and SG...
Page 26: ...xxiv 8265 PD and SG...
Page 32: ...1 6 8265 PD and SG...
Page 33: ...Chapter 2 MAPS Copyright IBM Corp 1998 2 1...
Page 134: ...3 32 8265 PD and SG...
Page 158: ...5 2 8265 PD and SG...