MAP 0290: MNTN Code 21 (Continued)
001
– Verify the PCMCIA card plugging.
Is the PCMCIA card correctly plugged?
Yes No
002
– Unplug and replug the PCMCIA card correctly.
Is the problem still present?
Yes No
003
– Problem determination completed. Go to Chapter 5, “CE Leaving Procedure” on page 5-1.
004
– Go to Step 005.
005
Is the connection between the control point card and switch card correct?
Yes No
006
– Fermely push the control point card onto the switch connector.
Is the problem solved?
Yes No
007
– Go to Step 009.
008
– Problem determination completed. Go to Chapter 5, “CE Leaving Procedure” on page 5-1.
009
– If the problem is still present after CPSW resets and with the PE agreement, replace the CPSW card.
See Chapter 4, “FRU Exchange” on page 4-1.
Symptom Explanation
Messages displayed:
LOAD OF OPERATIONAL CODE FAILED
2-32
8265 PD and SG
Summary of Contents for 8265 Nways ATM Switch
Page 1: ...8265 Nways ATM Switch IBM Problem Determination and Service Guide SY33 2128 00...
Page 2: ......
Page 3: ...8265 Nways ATM Switch IBM Problem Determination and Service Guide SY33 2128 00...
Page 8: ...vi 8265 PD and SG...
Page 10: ...viii 8265 PD and SG...
Page 11: ...Tables 3 1 Wraps available on WAN Modules 3 9 Copyright IBM Corp 1998 ix...
Page 12: ...x 8265 PD and SG...
Page 18: ...xvi 8265 PD and SG...
Page 26: ...xxiv 8265 PD and SG...
Page 32: ...1 6 8265 PD and SG...
Page 33: ...Chapter 2 MAPS Copyright IBM Corp 1998 2 1...
Page 134: ...3 32 8265 PD and SG...
Page 158: ...5 2 8265 PD and SG...
Page 159: ...Appendix A 8265 Part Numbers 8265 Parts Copyright IBM Corp 1998 A 1...
Page 160: ...1 Rear View A 2 8265 PD and SG...
Page 162: ...2 O O I I 3 4 5 A 4 8265 PD and SG...
Page 166: ...A 8 8265 PD and SG...
Page 168: ...X 2 8265 PD and SG...
Page 170: ......
Page 173: ......
Page 174: ...IBM SY33 2128...