1. Using the stand-alone diagnostic diskettes or the CD-ROM, start the using-system
|
diagnostics. (See the Diagnostic Information for Micro Channel Bus Systems manual
|
for instructions.)
The FUNCTION SELECTION menu is displayed.
2. Select DIAGNOSTIC ROUTINES
The DIAGNOSTIC MODE SELECTION menu is displayed.
3. Select SYSTEM VERIFICATION.
The DIAGNOSTIC SELECTION menu is displayed.
4. Select READ ANOTHER DIAGNOSTIC DISKETTE.
5. Insert the supplemental diskette into the diskette drive.
6. Press Enter.
The SSA extensions to the stand-alone diagnostics are installed and the SSA devices
configured.
7. Press the Cancel-function key to go to the DIAGNOSTIC OPERATING
INSTRUCTIONS menu.
Note: The identification of the Cancel-function key is displayed on the screen.
8. Press Enter to go to the FUNCTION SELECTION menu.
9. Select the function that you need (diagnostics or service aids).
Service Request Numbers (SRNs)
Service request numbers (SRNs) are generated for the 7133 by the system error-log
analysis, system configuration code, diagnostics, and customer problem-determination
procedures. SRNs help you to identify the cause of a problem, the failing field-replaceable
units (FRUs), and the service actions that might be needed to solve the problem.
The SRN Table
The table in this section lists the SRNs and describes the actions you should do. The
table columns are:
Abbreviations used in the table are:
SRN
The service reference number.
FRU list
|
The FRU or FRUs that might be causing the problem (see also “FRU Names
|
Used in the SRN Table” on page 2-3), and how likely it is (by percentage) that
|
the FRU is causing the problem.
Problem
A description of the problem and the action you must take.
DMA
Direct memory access
FRU
Field-replaceable unit
IOCC
Input/output channel controller
PAA
P = Adapter port number
AA = SSA address
(see also “Finding the Device When No Service Aids Are Available” on
page 1-58)
POS
Programmable option select (POS registers)
POST
Power-On Self-Test
2-2
7133 Service Guide
Summary of Contents for 7133 Series
Page 1: ...7133 SSA Disk Subsystems Service Guide SY33 0185 02...
Page 2: ......
Page 3: ...7133 SSA Disk Subsystems Service Guide SY33 0185 02...
Page 8: ...vi 7133 Service Guide...
Page 14: ...xii 7133 Service Guide...
Page 44: ...Labels Dummy Fan and Power Supply Assembly 1 30 7133 Service Guide...
Page 94: ...2 10 7133 Service Guide...
Page 110: ...2 2021 6 7133 Service Guide...
Page 114: ...2 2022 4 7133 Service Guide...
Page 138: ...2 2330 18 7133 Service Guide...
Page 146: ...2 16 7133 Service Guide...
Page 210: ...3 64 7133 Service Guide...
Page 222: ...4 12 7133 Service Guide...
Page 229: ......
Page 230: ...Part Number 32H6990 Printed in the United Kingdom 32H699 SY33 185 2...