MAP 2020: 7133 – Power
This MAP helps you to isolate FRUs that are causing a power problem on a 7133.
Attention: Unless the using system needs to be turned off for some other reason, do not
turn off the using system when servicing the 7133 or an SSA link. Power cables and
external SSA cables that connect the 7133 to the using system can be disconnected while
that system is running.
You are here because of one or more of the following:
A fan-and-power-supply assembly has its Fan-and-Power Check light on.
An SRN has sent you here.
Step 1
(from step 21 in “MAP 2010: 7133 – START”)
Does the fan-and-power-supply assembly in either position 2 or position 3 have its
Power light on?
NO
Go to step 2.
YES
Go to step 3 on page 2-2020-2.
Step 2
(from step 1)
Is power present at the mainline power source?
NO
|
For Models 010 and 020, go to the using-system Installation and Service Guide
for further isolation.
|
For Models 500 and 600, contact the site maintenance engineer or the
electricity supplier.
YES
Exchange the three-way power cable for a new one.
|
Note: On Models 500 and 600 in some countries, the mainline power plug
contains a fuse. Check the fuse before exchanging the power cable.
Chapter 2. Problem Determination Procedures
2-2020-1
Summary of Contents for 7133 Series
Page 1: ...7133 SSA Disk Subsystems Service Guide SY33 0185 02...
Page 2: ......
Page 3: ...7133 SSA Disk Subsystems Service Guide SY33 0185 02...
Page 8: ...vi 7133 Service Guide...
Page 14: ...xii 7133 Service Guide...
Page 44: ...Labels Dummy Fan and Power Supply Assembly 1 30 7133 Service Guide...
Page 94: ...2 10 7133 Service Guide...
Page 110: ...2 2021 6 7133 Service Guide...
Page 114: ...2 2022 4 7133 Service Guide...
Page 138: ...2 2330 18 7133 Service Guide...
Page 146: ...2 16 7133 Service Guide...
Page 210: ...3 64 7133 Service Guide...
Page 222: ...4 12 7133 Service Guide...
Page 229: ......
Page 230: ...Part Number 32H6990 Printed in the United Kingdom 32H699 SY33 185 2...