SW-4000T-MCL User Manual (2.0)
Setting List
- 74 -
UserSetControl
Configure user settings.
Related Topic:
User Set Control
Item
Setting
Range
Default
Value
Description
UserSetSelector
-
0: Default
Select the user settings.
0: Default - Invalid when executing UserSetSave
1: User1
2: User2
3: User3
UserSetLoad
-
-
Read the user settings. When selecting
Default
for UserSetSelector, the
factory settings are loaded.
UserSetSave
-
-
Save the current setting values as user settings. Invalid when
UserSetSelector is set to Default.
TransportLayerControl
Display information on transport layer control.
Transport Layer Control Item
Setting
Range
Default
Value
Description
ClConfiguration
0: Base
1: Medium
2: Full
4: EightyBit
0:Base
(fixed)
Set the Camera Link configuration.
CameraLinkClockFrequency
0: 85MHz
1: 63.75MHz
2: 42.5MH
0: 85MHz
Set Camera Link clock frequency.
SwapBandR
0: Off
1: On
0: Off
Specify whether to swap Blue and Red to enable support for
connecting a particular grabber board.
AdditionalInformation
0: Off
1: On
1: On
CableEmphasis
Related Topic:
0: Normal
1: Medium
2: Strong
1: Medium
Set CableEmphasis. When set to Medium or Strong, you may be
able to extend the camera link cable length.