SW-4000T-MCL User Manual (2.0)
Short ASCII Command List
- 88 -
Acquisition Control
Name
Access
Short
ASCII
Values
Default
Value
Example / Description
ExposureTimeMode
R/W
ETM
0:Common
1:Individual
0
ETM=[Param.]<CR><LF>
ETM?<CR><LF>
Select the exposure time mode.
Common
: Set the common value for R, G and
B channels.
Individual
: Set the values for the R, G, and B
channels individually
ExposureTime[Common]
R/W
PE
300 ~ 1514908
Unit: 10ns (100 = 1us)
27847
PE=[Param.]<CR><LF>
PE?<CR><LF>
When ExposureTimeMode is set to Common,
set the exposure time in Common mode.
ExposureTime
[Red]
R/W
PER
300 ~ 1514908
Unit: 10ns (100 = 1us)
27847
PER=[Param.]<CR><LF>
PER?<CR><LF>
Set the exposure time for the Red channel.
Note:
ExposureTimeMode must be set to
Common
.
ExposureTime
[Green]
R/W
PEG
300 ~ 1514908
Unit: 10ns (100 = 1us)
27847
PEG=[Param.]<CR><LF>
PEG?<CR><LF>
Set the exposure time for the Green channel.
Note:
ExposureTimeMode must be set to
Common
.
ExposureTime
[Blue]
R/W
PEB
300 ~ 1514908
Unit: 10ns (100 = 1us)
27847
PEB=[Param.]<CR><LF>
PEB?<CR><LF>
Set the exposure time for the Blue channel.
Note:
ExposureTimeMode must be set to
Common
.
AutoReset
R/W
ARS
0: Off
1: On
0
ARS=[Param.]<CR><LF>
ARS?<CR><LF>
Set the AutoReset. (When auto reset mode is
enabled, LVAL, DVAL, and video are not output
while the trigger input is interrupted. When
resuming trigger input, output of LVAL, DVAL,
and video is resumed.)