SW-4000T-MCL User Manual (2.0)
Setting List
- 76 -
Pulse Generator Item
Setting Range
Default Value
Description
PulseGeneratorEndPoint
(ms)
(1 /
PulseGeneratorClock
(MHz)) to (1048575 /
PulseGeneratorClock
(MHz))
33.3333
Set the start point of the Low interval in
milliseconds. When the counter reaches this
value, the output will be 0. The setting range varies
depending on the ClockPreScaler value.
PulseGeneratorEndPoint =
1/PulseGeneratorClock *
PulseGeneratorEndPoint
PulseGeneratorPulseWidth
(ms)
-
33.3333
Display the High interval width of the pulse in
milliseconds. The duration between the Start Point
and End Point is calculated. The setting range
varies depending on the ClockPreScaler value.
PulseGeneratorPulseWidth =
1/PulseGeneratorClock *
(PulseGeneratorEndPoint -
PulseGeneratorStartPoint)
PulseGeneratorRepeat
Count
0 ~ 255
0
Set the repeat count for the counter. When this is
set to 0, a free counter is enabled with no repeat
limit.
PulseGeneratorClear
Activation
0: Off
1: Level High
2: Level Low
4: Rising Edge
8: Falling Edge
0: Off
Set the clear signal condition for the count clear
input of the pulse generator.
PulseGeneratorClear
Source
-
0: Low
Select the count clear input signal source.
0: Low
1: High
7: ExposureActive
9: LVAL
10-13: PulseGenerator0-3
14-17: UserOutput0-3
20: Line4: TTL In1
21: Line5: Opt In1
23: Line7 - CC1
24: Line10: TTL In2
26: NAND0 Out
27: NAND1 Out
28: Line13: TTL In3
29: EncoderTriger
30: EncoderDirection
Note:
(
※
)Disabled if the PulseGenerator is selected
in PUlseGeneratorSelector.