79
b. Acceleration and deceleration, speed data designation
This is an effective function when the positioning data designated mode is selected.
[1] Set the acceleration and deceleration, and speed data designation to each designated register at the
same time when setting the target position data in a. or before setting it.
Note that setting of parameter No.9 “Acceleration and deceleration initial value” is not applied unless
the acceleration and deceleration is set. And, stop status is kept when speed is not set or is set to “0.”
Alarm does not occur.
[2] It is transmitted together with the target position data at ON edge of the CSTR (start) (at startup of
signal).
[3] It is possible to change the acceleration and deceleration and speed data during movement.
To change the acceleration and deceleration or speed during movement, turn ON the CSTR after
changing the acceleration and deceleration and speed data.
In this case, keep the CSTR ON for tdpf or longer. And take an interval time of 1Mt or longer until
turning ON the next CSTR after turning OFF the CSTR.
When changing the speed by changing the setting to “0” during movement, it decelerates and stops.
Alarm does not occur.
CAUTION
1. It is necessary to set the target position data even when changing only the acceleration and
deceleration/speed data during movement.
2. It is necessary to set the acceleration and deceleration/speed data even when changing only the target
position during movement.
Summary of Contents for RCM-GW-CC
Page 1: ...IAI America Inc CC Link RCM GW CC Gateway Unit Operation ManualFirst Edition...
Page 4: ......
Page 10: ...6 1 5 How to identify model RCM GW CC Basic model For CC Link Gateway unit...
Page 12: ...8 2 2 External dimension drawing Mounting dimension...
Page 78: ...74...
Page 82: ...78 Position data measurement value Present position 1 2 3 4 4 5 6 7...
Page 84: ...80 Speed acceleration and deceleration set value Actuator speed Speed n2 Speed n3 1 2 3...
Page 88: ...84 Command position No Completion position No 1 2 3 4 5 6...
Page 91: ...87...
Page 93: ...89...
Page 125: ...121 No 3 Axis 1 pause No 3 Axis 1 pause lamp No 3 Axis 1 STP...
Page 130: ...126...
Page 131: ......