93
8.3. Master PLC address assignment
The basic concept of address assignment (memory map) for the CC-Link master PLC has been explained in
5.2. This section explains a case when the gateway unit is a remote station. If the gateway unit is a remote
device station (remote station which handles bit information and word information), the number of exclusive
stations depends on the operation mode.
Input and output region
Operation mode
Remote I/O
Remote
register
Number of exclusive
stations
Number of
controlled axes
Position data limit designation
8 word
16 word
4
14
Position No. designation
8 word
16 word
4
14
Normal position data designation
8 word
16 word
4
7
Push operation data designation
8 word
16 word
4
3
Small
10 word
24 word
* Depends on setting
16 max.
Middle
20 word
48 word
* Depends on setting
16 max.
Simple direct
value/Position No.
designation
Large
24 word
64 word
* Depends on setting
16 max.
* Number of links per one CC-Link remote station is 32 points (two words) for remote input and output, and
four points (four words) respectively for remote register, then a maximum 64 stations per one system can be
linked.
Number of links per one station can be expanded by the expanded cyclic setting.
Summary of Contents for CC-Link
Page 1: ...IAI America Inc CC Link RCM GW CC Gateway Unit Operation ManualFirst Edition ...
Page 4: ......
Page 10: ...6 1 5 How to identify model RCM GW CC Basic model For CC Link Gateway unit ...
Page 12: ...8 2 2 External dimension drawing Mounting dimension ...
Page 78: ...74 ...
Page 82: ...78 Position data measurement value Present position 1 2 3 4 4 5 6 7 ...
Page 84: ...80 Speed acceleration and deceleration set value Actuator speed Speed n2 Speed n3 1 2 3 ...
Page 88: ...84 Command position No Completion position No 1 2 3 4 5 6 ...
Page 91: ...87 ...
Page 93: ...89 ...
Page 125: ...121 No 3 Axis 1 pause No 3 Axis 1 pause lamp No 3 Axis 1 STP ...
Page 130: ...126 ...
Page 131: ......