![IAI CC-Link Operation Manual Download Page 61](http://html1.mh-extra.com/html/iai/cc-link/cc-link_operation-manual_604089061.webp)
57
Signal type
Application
Signal
name
Contents Detail
Positioning
width
designation
24 bit data
-
24 bit integer (Unit: 0.01mm)
Set it in hexadecimal number.
Example) In the case of +25.4mm, designate it as
0009EC
H
(decimal 2540).
●
Set position data in a range of soft stroke.
●
Designate push operation direction in DIR.
●
When positioning width designating data is not
set, note that setting of parameter No.10
“Positioning width initial value” is not set.
F/b 15
-
Cannot be used
E/b 14
DIR
Designation of push direction
(0
-
Home return direction, 1
-
Home return
reverse direction)
D/b 13
PUSH
Push operation mode designation
C/b 12
SON
Servo on command
B/b 11
STP
Pause command
A/b 10
HOME Home return command
9/b9 CSTR
Start command
PLC outp
ut
Control
signal
8/b8 RES
Reset command
F-8/b15-8
-
Cannot be used
7/b7
EMGS On emergency stop
6/b6 PSFL
Push
outside
5/b5
PWR
Controller preparation completion
4/b4
SV
Operation preparation completion (Servo on status)
3/b3 MOVE
On
moving
2/b2
HEND Home return completion
1/b1 PEND
Positioning
completion
Status signal
0/b0 ALM
Alarm
occurring
Present
position data
24 bit data
-
24 bit integer with sign (Unit: 0.01mm)
Data of present position is outputted in
hexadecimal number.
Example) In the case of +25.4mm, the data is
0009EC
H
(decimal 2540).
(Note)
●
When the integer is negative, it is indicated by
complement of 2, therefore, the uppermost bit
becomes “1.”
PLC in
put
-
-
b15-8
Cannot be used
Summary of Contents for CC-Link
Page 1: ...IAI America Inc CC Link RCM GW CC Gateway Unit Operation ManualFirst Edition ...
Page 4: ......
Page 10: ...6 1 5 How to identify model RCM GW CC Basic model For CC Link Gateway unit ...
Page 12: ...8 2 2 External dimension drawing Mounting dimension ...
Page 78: ...74 ...
Page 82: ...78 Position data measurement value Present position 1 2 3 4 4 5 6 7 ...
Page 84: ...80 Speed acceleration and deceleration set value Actuator speed Speed n2 Speed n3 1 2 3 ...
Page 88: ...84 Command position No Completion position No 1 2 3 4 5 6 ...
Page 91: ...87 ...
Page 93: ...89 ...
Page 125: ...121 No 3 Axis 1 pause No 3 Axis 1 pause lamp No 3 Axis 1 STP ...
Page 130: ...126 ...
Page 131: ......