64
Details of input and output signal
Signal type
Bit
Signal
name
Contents Detail
Target
position
data
32 bit
data
-
This is a 32 bit integer with sign (Unit: 0.01mm),
and is set in hexadecimal number.
Example) In the case of +25.4mm, set it to
0009EC
H
(decimal 2540).
●
When the integer is negative, it is indicated
by complement of 2, therefore, the
uppermost bit becomes “1.”
-
Movement
parameter
position No
16 bit
data
-
Set movement parameters other than target
position data on the position table, however,
designate the position No. in hexadecimal
number.
-
b15-b13
-
Cannot be used.
b12
SON
Servo on command
b11 STP
Pause
command
b10
HOME
Home return command
b9 CSTR
Start
command
b8 RES
Reset
command
PLC outp
ut
Control
signal
b7-b0
-
Cannot be used.
Present
position
data
32 bit
data
-
This is a 32 bit integer with sign (Unit: 0.01mm),
and the present position data is outputted in
hexadecimal number.
Example) and (Note) are the same as those for
the target position data.
b15-b9
-
Cannot be used.
b8 PMSS
PIO/Modbus switching status
0: PIO, 1: Modbus
Switching is performed by PIO/Modbus
switching command.
b7
EMGS
Emergency stop status
b6 PSFL
Push
outside
-
b5
PWR
Controller preparation completion
b4 SV
Operation preparation completion (Servo on
status)
b3 MOVE
On
moving
b2
HEND
Home return completion
b1 PEND
Positioning
completion
PLC in
put
Position
data
designation
b0 ALM
Alarm
occurring
Summary of Contents for CC-Link
Page 1: ...IAI America Inc CC Link RCM GW CC Gateway Unit Operation ManualFirst Edition ...
Page 4: ......
Page 10: ...6 1 5 How to identify model RCM GW CC Basic model For CC Link Gateway unit ...
Page 12: ...8 2 2 External dimension drawing Mounting dimension ...
Page 78: ...74 ...
Page 82: ...78 Position data measurement value Present position 1 2 3 4 4 5 6 7 ...
Page 84: ...80 Speed acceleration and deceleration set value Actuator speed Speed n2 Speed n3 1 2 3 ...
Page 88: ...84 Command position No Completion position No 1 2 3 4 5 6 ...
Page 91: ...87 ...
Page 93: ...89 ...
Page 125: ...121 No 3 Axis 1 pause No 3 Axis 1 pause lamp No 3 Axis 1 STP ...
Page 130: ...126 ...
Page 131: ......