Page 34
autocut 5-32cts user manual edItIon II 2015-01-16
5.7.2 Machine Parameter
this menu have settings for the encoder and the servomotor for calibration purpose.
the parameters are only accesible with a password and reserved for service personell only.
1. Extern encoder pulses/rev:
set encoder type. default 1000 pulses/rev.
2. Measuring Wheel dia.:
only information, change the value and save in each
recipe in the menu ”Article-Recipe”
3. Actual mm= true mm (0,5-1,5):
calibration off output cut length.
adjust if requested length always is different to actual output length.
3. Acceleration (50-5000msec):
set the acceleration time for the servomotor.
factory default 500msec.
4. deceleration (50-5000msec):
set the deceleration time for the servomotor.
factory default 500msec.
5. Machine Info:
Info about the machine and software program.
6. Prev:
closes this menu and open previous menu.
7. Home:
Press to return to ”Main”menu.
HYDROSCAND MACHINE AB
Kungsvägen 22
Phone: +46 (0)225 - 573 30
S-783 35 Säter
Fax:
+46 (0)225 - 501 08
Sweden
Web:
www.hydroscand-machine.se
Edition 7-00
MANUAL-E
Page 23
7.52 Machine Parameter
This menu have settings for the encoder and the servo motor for calibration purpose.
The parameters are only accesible with a password and reserved for service personell only.
1.
Extern encoder pulses/rev:
Set encoder type. Default 1000 pulses/rev.
2.
Measuring Wheel Dia.:
Only information, change the value and save in each
recipe in the menu "Article-Recipe"
3.
Actual mm= true mm (0,5-1,5):
Calibration off output cut length.
Adjust if requested length always is different to actual output length.
3.
Acceleration (50-5000msec):
Set the acceleration time for the servomotor.
Factory default 500msec.
4.
Deceleration (50-5000msec):
Set the deceleration time for the servomotor.
Factory default 500msec.
5.
Machine Info:
Info about the machine and software program.
6.
Prev:
Closes this menu and open previous menu.
7.
Home:
Press to return to "Main" menu.
1
2
3
4
5
6
7