Page 17
autocut 5-32cts user manual edItIon II 2015-01-16
5.5.5 LENgTH CoNTRoL
this menu is for monitoring and setting of length tolerances.
1. Requested length:
display for requested cut length.
2. Ext. Current Length:
display for actual output length.
3. Length tol:
set the required plus tolerance with the pop-up window by
touching the display field. Confirm value with Enter key: Too narrow tolerance will cause
length error and stop in the batch.
4. Length tolerance -:
set the required minus tolerance with the pop-up window by
touching the display field. Confirm value with Enter key: Too narrow tolerance will cause
length error and stop in the batch.
5. Home:
Press to return to ”Main” menu.
LENGTH CONTROL
LENGTH ERROR
00000
0000000
00
00
HOME
5
4
3
2
1
Requested length
mm
mm
mm
mm
Ext.Current Length
Length tol
Length tolerance -