autocut 5-32cts user manual edItIon II 2015-01-16
5.5.6 Machine parameter menu
this menu is for calibration of encoder and acceleration and deceleration of feeding belt.
the parameters are only accesible with a password and reserved for service personell only.
1. Extern encoder pulses/rev:
set encoder type. default 1000 pulses.
2. a) Actual mm= true mm (0,5-1,5):
calibration off out put length.
b) length control calibration: calibration of length control function.
3. Acceleration (50-5000msec):
set the acceleration time for the belt.
4. deceleration (50-5000msec):
set the deceleration time for the belt.
5. Home:
Press to return to ”Main” menu.
MACHINE PARAMETER
00000
0000000
00
00
HOME
5
4
3
2
1
Extern encoder pulses/rev
Pulses
mm
msec
msec
Ext.Current Length
Acceleration (50-5000 msec)
Deceleration (50-5000 msec)