12
5.5KW ELECTRICAL CONNECTIONS
5.5KW electric heat “Main” control with independent heater wiring
FOR SYSTEM MODEL CODES (Label located on outside of box)
ES8848D ES8848E ES8850F
ES8850D ES8850E CS8800B
GROUND
GROUND
GROUND
H L
C
L
C L
L
L
C
L
C
PUMP
1
PUMP
2
BLOWER
H L
C
OZONE
12V
LIGHT
L
C
PUMP
3
L
L
120V
LIGHT
FIREMANS
SWITCH
FUSE 30A
FUSE 30A
J35
MAIN
MAIN
J34
Heater main wires
Ground
Line 1
Line 2
GFCI BREAKER #2
(240v 3-Wire only)
see page 8 for breaker sizing
GFCI BREAKER #1
(240v 4-Wire only)
Neutral
Line 1
Line 2
Ground
see page 8 for breaker sizing
For correct GFCI breaker sizing, Reference the GFCI breaker sizing matrix page in
this manual
Programming allowing heater and high speed pump operation simultaneously
requires “dip switch” change on board (see figure below)
DUAL SOURCE WIRE CONNECTION
Blue
Black
Move dip switch #2 - #4 to the ON position
to allow high speed pump(s) and heater to
function simultaneously
Fig. A
SwtichBank ON:
A2: Add 1 HS Pump with heat
A3: Add 2 HS pumps with heat
A4: Add 4 HS pumps with heat