10
208V ELECTRICAL CONNECTIONS CONSIDERATIONS
Heater main wires
electric heater models
only
GROUND
GROUND
GROUND
H L
C
L
C L
L
L
C
L
C
PUMP
1
PUMP
2
BLOWER
H L
C
OZONE
12V
LIGHT
L
C
PUMP
3
L
L
120V
LIGHT
FIREMANS
SWITCH
FUSE 30A
FUSE 30A
J35
MAIN
MAIN
J34
J58
J53
J45
J79
J54
J77
J75
J78
J36
J12
J88
J62
J37
J4
J1
J47
J72
J42
J3
J61
J51
J52
J98
J56
J57
J55
J59
J41
J60
J49
J48
Ground
Line 1
Line 2
GFCI BREAKER #1
(240v 4-Wire only)
Neutral
Line 1
Line 2
Ground
see page 8 for breaker sizing
GFCI BREAKER #2
(240v 3-Wire only)
see page 8 for breaker sizing
Move dip switch #2 - #4 to the ON position
to allow high speed pump(s) and heater to
function simultaneously
Fig. A
Red
Black
SwtichBank ON:
A2: Add 1 HS Pump with heat
A3: Add 2 HS pumps with heat
A4: Add 4 HS pumps with heat
IMPORTANT 208V INFORMATION
The system has the capability to operate on 208V provided certain changes are made
to the circuit board transformer and input wiring. When operating on 208V a compatible
pump must be used. A compatible pump would be either 120V or marked specically
for use with 208V.
**240V pumps provided by Hydro-Quip are NOT 208V compatible
**
Below is an illustration of the system wiring as shipped from Hydro-Quip. Follow the
instructions on page #X and the illustration on page #X to make the system compatible
with 208V incoming power.