Instruction
Wiring Instruction from 220-240v. to 208v. power supply
Ÿ
Information provided for Balboa BP-2000 system board only
Ÿ
1 logic jumper P/N 34-20564 is included with this instruction
Ÿ
Terminal Block wiring label
Ÿ
New diagram# 5195-5197
WARNING
!
System power must be off when removing or installing logic jumpers
Logic jumper(s) must be programmed to match incoming power supply voltage.
Use these steps if a programming change is required
Step #1
Disconnect power
Step #2
Locate transformer programing bank at position J24 on PCB
Step #3
Conrm system supply voltage with your electrician.
Step #4
Use diagrams below to correctly place logic jumper(s) to match system supply voltage
(Dia #1 = 220-240V. ) (Dia #2 = 208V)
Step #5
Remove and Discard the jumper wire connecting J41 to J12
Step #6
Remove and Discard the jumper wire connecting J51 to J88
Step #7
The wire currently connected to J36 must be relocated to J51
Step #8
The wire currently connected to J52 must be relocated to J75
Step #9
The wire currently connected to J58 must be relocated to J52
Step #10
The wire currently connected to J49 must be relocated to J98