![Hydronix Hydro-Control VI Operator'S Manual Download Page 79](http://html.mh-extra.com/html/hydronix/hydro-control-vi/hydro-control-vi_operators-manual_2192336079.webp)
Hydro-Control VI Operators Guide HD0456 Rev 1.7.1 79
Appendix A
Diagnostics
The following tables list the most common faults found when using the controller. If you are unable to
diagnose the problem from this information, please contact Hydronix technical support on +44 1483
468900 or by email: [email protected].
Symptom: Displays shows ‘Searching For Sensor’ - no output from sensor
Possible explanation Check
Required result
Action required on failure
No power to sensor.
DC power at rear of
Hydro-Control VI,
pins 31 + 33
+24v DC
Locate fault in power
supply/wiring
Sensor has temporarily
locked up
Power down and re-
power sensor
Sensor functions
correctly
Check sensor connector pins
Sensor MIL-Spec
connector pins are
damaged
Disconnect the
sensor cable and
check if any pins are
damaged.
Pins are bent and
can be bent to
normal to make
electrical contact.
Check sensor configuration by
connecting to a PC.
Internal failure or
incorrect configuration
Connect the sensor
to a PC using the
Hydro-Com
software and a
suitable RS485
converter.
Digital RS485
connection is
working.
Digital RS485 connection is
not working. Sensor should be
returned to Hydronix for repair.
Symptom: Incorrect sensor readings
Possible explanation Check
Required result
Action required on failure
Sensor Unscaled
readings are incorrect
Press Display
Unscaled on the
Overview Screen
Readings should be
the following:
Sensor exposed to
air = close to zero.
Hand on sensor =
75-85
Contact Hydronix for more
details.
Incorrect recipe
calibration
Check recipe for
parameters
‘moisture gain’ and
‘moisture offset’
Moisture offset = 0
to -5
Moisture gain =
0.12 to 3
Recalibrate recipe as per
instructions in Chapter 8.
Moisture signal should be
stable at the end of the first
and final mix times for
increased accuracy.
Summary of Contents for Hydro-Control VI
Page 4: ...4 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 6: ...6 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 8: ...8 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 10: ...10 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 18: ...Navigation Chapter 2 18 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 20: ...Plant Operator Controls Chapter 3 20 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 34: ...Editing Recipes Chapter 6 34 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 40: ...Running the First Mix Chapter 7 40 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 56: ...Using Moisture Control Chapter 8 56 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 70: ...Setting Up User Accounts Chapter 11 70 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 72: ...Remote Support Chapter 12 72 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 86: ...Document Cross Reference Appendix C 86 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...