Hydro-Control VI Operators Guide HD0456 Rev 1.7.1 45
Task
Action
If calibrating using pre-wet in calculation mode enter a pre-
wet target value.
Enter a moisture target, for the main water addition and then
press OK.
The moisture target value is only used to set the display
value that the operator sees on the Overview Screen. It can
be any value chosen by the user, and does not have to be
an accurate value. However, if a real moisture value is
required then one of the following values can be entered:
•
The theoretical value from the mix design
•
The moisture calculated from the raw materials
•
The result of a bake out of the calibrated batch
•
If the result of a bake out is used then it should
be noted that this should be done as quickly as
possible as it will be affected by the hydration
process. The concrete should be spread thinly
before performing the bake out.
Enter the Moisture Target value
Press OK
If the mix consistency would have been improved by adding
or subtracting a certain quantity of water, then this value can
be added at this point, and the OK button pressed.
Enter the Water Trim value
Press OK
If no dry weight has been entered into the recipe, then the
calibration process will prompt the operator to enter one at
this point.
Enter the Dry Weight value
Press OK
Select which sensor measurement mode to use (only
available with compatible sensors)
Enter Measurement mode
Press OK
The Hydro-Control will then display a summary of the
parameters that the calibration will be based on. Check the
details and press OK.
Press the Menu button and then the Overview button to
return to the Overview Screen.
Press OK
After calibration it is always good practice to monitor the following batches of the same recipe
and to check the strength and quality of the mix output.
Summary of Contents for Hydro-Control VI
Page 4: ...4 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 6: ...6 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 8: ...8 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 10: ...10 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 18: ...Navigation Chapter 2 18 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 20: ...Plant Operator Controls Chapter 3 20 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 34: ...Editing Recipes Chapter 6 34 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 40: ...Running the First Mix Chapter 7 40 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 56: ...Using Moisture Control Chapter 8 56 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 70: ...Setting Up User Accounts Chapter 11 70 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 72: ...Remote Support Chapter 12 72 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 86: ...Document Cross Reference Appendix C 86 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...