![Hydronix Hydro-Control VI Operator'S Manual Download Page 31](http://html.mh-extra.com/html/hydronix/hydro-control-vi/hydro-control-vi_operators-manual_2192336031.webp)
Hydro-Control VI Operators Guide HD0456 Rev 1.7.1 31
Recipe parameter
Description
Wet Mix Time
When using Auto-track control, this is the amount of time that the
Wet Mix must be within the Wet Mix Deviation below to continue.
If the sensor signal has not stabilised within this window by the end
of the Wet Mix Time, the system will prompt the operator to
continue regardless of whether it has stabilised or not.
Wet Mix Deviation
This is the maximum deviation that the sensor signal must be within
in order for the system to continue.
Using the Next button gives Page 3 of the recipe editor screen.
Figure 13: The recipe editor screen (page 3)
1.6
Calculation Mode Settings
Recipe parameter
Description
Pre-wet Moisture Offset 1
Pre-wet Moisture Gain 1
These are the calibration coefficients for the pre-wet phase of the
recipe. These define the relationship between the amount of
moisture in the batch and the unscaled sensor value. These are
automatically calculated when you calibrate a recipe.
Moisture Offset 1
Moisture Gain 1
These are the calibration coefficients for the recipe. These define
the relationship between the amount of moisture in the batch and
the unscaled sensor value. These are automatically calculated
when you calibrate a recipe.
Moisture Offset 2
Moisture Gain 2
These are the calibration coefficients for the recipe with the
admixture in. These are automatically calculated when you
calibrate a recipe using the two step preset method.
Use Pre-wet value for main
water
If enabled the Hydro-Control VI will use the reading measured at
the end of the pre-wet mix rather than the dry mix to calculate how
much water to add in the main water addition
Summary of Contents for Hydro-Control VI
Page 4: ...4 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 6: ...6 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 8: ...8 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 10: ...10 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 18: ...Navigation Chapter 2 18 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 20: ...Plant Operator Controls Chapter 3 20 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 34: ...Editing Recipes Chapter 6 34 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 40: ...Running the First Mix Chapter 7 40 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 56: ...Using Moisture Control Chapter 8 56 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 70: ...Setting Up User Accounts Chapter 11 70 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 72: ...Remote Support Chapter 12 72 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 86: ...Document Cross Reference Appendix C 86 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...