![Hydronix Hydro-Control VI Operator'S Manual Download Page 32](http://html.mh-extra.com/html/hydronix/hydro-control-vi/hydro-control-vi_operators-manual_2192336032.webp)
32 Hydro-Control VI Operators Guide HD0456 Rev 1.7.1
Reset Calibration
Resets the Calculation Mode calibration coefficients to the default value
View Calibration
Opens the MixTrace Graph of the Mixlog used to calibrate the recipe. Only available if the recipe
has been calibrated.
1.7
Auto Mode Settings
Recipe parameter
Description
Local Auto Control
This parameter becomes active when the recipe Control Method is
set to Auto. In normal use the Hydro-Control will work without a
problem with the Auto Parameters in the System Parameters.
However it may be necessary to set up specific parameters for
difficult mixes. This allows the system parameters to be overridden
and the local parameters to be used to control the rate of the water
addition.
Proportional Gain
This parameter is used by the control mode to adjust the rate that
the water is added to the mixer.
This defines the initial speed of the water into the mixer.
Integral Gain
This parameter is used by the control mode to adjust the rate that
the water is added to the mixer.
This adjusts the rate of the water addition based on the amount of
time the addition has taken. This can be used to correct an offset
at the end of the water addition without having to use excess
Proportional Gain which can cause overshoot.
Derivative Gain
This parameter is used by the control mode to adjust the rate that
the water is added to the mixer.
It adjusts the rate of water addition based on the rate of change of
the difference between the current moisture and the target.
1.8
Admix Settings
Recipe parameter
Description
Admix Enable
This is the point in % during the main water phase that the Admix
signal will be set.
Admix Amount
Not used by the Hydro-Control but appears in the Recipe. This is
the amount of admix stated in the mix design. This can be manually
input for information only.
Summary of Contents for Hydro-Control VI
Page 4: ...4 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 6: ...6 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 8: ...8 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 10: ...10 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 18: ...Navigation Chapter 2 18 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 20: ...Plant Operator Controls Chapter 3 20 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 34: ...Editing Recipes Chapter 6 34 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 40: ...Running the First Mix Chapter 7 40 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 56: ...Using Moisture Control Chapter 8 56 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 70: ...Setting Up User Accounts Chapter 11 70 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 72: ...Remote Support Chapter 12 72 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 86: ...Document Cross Reference Appendix C 86 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...