ContaminationSensor CS 1000
Technical data
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 100 / 108
BeWa CS1000 3247149p 240 en-us 2011-02-11.doc
2011-02-11
Technical data
General data
Mounting position
Any (recommended: vertical position)
Self-diagnosis
continuously with error indication via status LED
and display
Display (only CS 1x2x)
LED, 6 digits, in 17 segment format each
CS 12xx
ISO / SAE
Measured variables
CS 13xx
ISO / SAE / NAS
Flow
ml/min
Out
mA or VDC depending on model
Drive
%
Service variables
Temp
°C and °F
Ambient temperature range
-30 … +80 °C / -22 … 176 °F
Storage temperature range
-
40 … +80 °C / -40 … 176 °F
Relative humidity
max. 95%, non-condensing
CS 1xx0
FPM
Material of sealings
CS 1xx1
EPDM
Protection class
III (low voltage protection)
IP class
IP67
Weight
~ 1.3 kg
Electrical data
Connection plug
M12x1, 8 pole, specified in DIN VDE 0627
Supply voltage
9 … 36 V DC, residual ripple < 10%, (protected
against polarity reversal)
Power consumption
3 Watt max.
sAnalog output
2-conductor technology
4 … 20 mA active output (max. burden 330
Ω
) or
2 … 10 V active output (min. load resistor 820
Ω
)
Switching Output
passive, n-switching Power MOSFET:
maximum switching current 2 A,
maximum switching voltage 30 V DC,
dead open
RS485 interface
2 wire, half duplex
HSI (
H
YDAC
S
ensor
I
nterface)
1 wire, half duplex