ContaminationSensor CS 1000
Analog output
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 58 / 108
BeWa CS1000 3247149p 240 en-us 2011-02-11.doc
2011-02-11
SAE Class A / B / C / D
The SAE class A/B/C/D signal consists of 4 measured values transmitted with the
following time-coded time slices:
4,0
I (mA)
U (V)
t (ms)
4,8
Low
20,0
19,2
High
High
Low
4,5
4,3
4,1
19,7
19,5
300
3000
1
3
5
7
1
2
4
6
8
2,0
2,05
2,25
2,4
9,85
9,75
2,15
9,6
0,0
19,8
10,0
9,9
Ti
me
Signal
Size
Signal duration
per pulse
in ms
Current (I) / Voltage (U)
1
Identifier
SAE A
300
High / Low
2 Measured
value
SAE A
3000
Current/Voltage for measured value
3
Identifier
SAE B
300
High / Low / High / Low
4 Measured
value
SAE B
3000
Current/Voltage for measured value
5
Identifier
SAE C
300
High / Low / High / Low / High / Low
6 Measured
value
SAE C
3000
Current/Voltage for measured value
7
Identifier
SAE D
300
High / Low / High / Low / High / Low / High / Low
8 Measured
value
SAE D
3000
Current/Voltage for measured value
SAE A / SAE B / SAE C / SAE D
The SAE x setting enables the value of a class to be continuously output via the
analog output.