ContaminationSensor CS 1000
CS1000 hydraulic installation
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 22 / 108
BeWa CS1000 3247149p 240 en-us 2011-02-11.doc
2011-02-11
Selecting the measurement point
In order to obtain cleanliness values that are continuous and coherent in real time,
select a suitable measuring point according to the following guidelines:
A
B
2
A
B
1
3
A
2
1
B
WRONG WRONG
OK
1
Select the measurement point so that the sample measured comes from a
turbulent location, with a good flow. For example: on a pipe elbow, etc.
2
Install the sensor near the measurement point to achieve as timely results
as possible.
3
During installation, avoid creating a "siphon" trap for particle deposits in the
line (sedimentation).