2012 by Huchez Treuils S.A.S.
Translation of the original instructions manual
34
EN
Reproduction prohibited
To reset to the default setting E12 press the stop reset button
or the ignition key on the AE unit.
With SJ200 inverter (HITACHI model)
Use of the integrated keyboard
Adjusting limitation (current) using the SJ200 inverter:
1/ Winch switched on displays
0000
,
button displays
D001
2/ Arrow 2 = H - - - .
3/ Arrow 2 = C - - - .
4/ Press
=
C001
then arrow 1 until
C041
is displayed
5/ Press
, the value in ampere is displayed, press
until the maximum value then press
to confirm
6/ Press
returns to
C041
, then press the
button three times for C - - -
7/ Press
for
D002
then press
,
0000
is displayed, direct ampere reading
8/ Load the winch at the required value, then test and take ampere reading (e.g. 5.00 A)
9/ Return to C041 to adjust the value determined in
D002
: press
+ press
three times, press
+ press
until
C041
value is adjusted (e.g. 5.00 A or lower to stop below the reading) in amperes then press
to
confirm