SmartLogger1000
User Manual
6 User Interface
Issue 12 (2019-01-15)
Copyright © Huawei Technologies Co., Ltd.
94
LCD
Operation Procedure
6. Choose
Running Param.
and press
.
----End
Parameter Description
describes the PID module running parameters.
Table 6-4
Running parameter descriptions
No.
Parameter
Name
Function
Parameter
Value
Description
1
Offset mode Specifies the
offset mode of
the PID module.
Disabled
Set this parameter to
Disable
if the PID module is
not required.
N/PE
Set this parameter to
N/PE
if the PID module is
required to use voltage output from the inductor
virtual midpoint N.
PV/PE
Set this parameter to
PV/PE
if the PID module is
required to use voltage output from the negative PV
terminal.
This mode is applicable only to SUN8000.
Automatic
In the SUN2000,
Automatic
indicates the N/PE
offset mode.
2
Output
enabled
Specifies whether
the PID module
Enable
Set this parameter to
Enable
to allow the PID
module output.