6 User Interface
Issue 12 (2019-01-15)
Copyright © Huawei Technologies Co., Ltd.
88
LCD
Procedure
6. Choose
Running Param.
and press
.
Baud rate
is set to
115200
by default,
which provides optimal communications
performance and does not need to be
changed.
When
Anti-crosstalk
is set to
Enable
, the
inverters equipped with the PLC STA
module on the SN list can connect to the
network.
When
Box-type TF No.
and
Winding No.
of the PLC CCO are consistently set, the
inverters equipped with the PLC STA
module can be automatically added to the
STA list.
When the PLC CCO is SUN2000
V100R001C72SPC104 or later versions,
you can set
Networking
. When the
SmartLogger communicates with the
SUN2000 over PLC, set
Networking
to
Enable
(
Enable
by default). When the
SmartLogger communicates with the
inverter over RS485 only, set
Networking
to
Disable
.
----End
6.2.13 Sending a Reset Command to the PLC
You can send a reset command to the PLC on the monitoring panel.
Procedure
The following table describes the steps for sending a reset command to the PLC. The
parameter values in the following figures are for reference only.
LCD
Operation Procedure
1. On the default screen, press
to enter
the main menu.