5.18
Caution!
If you do not adjust the flow according to these instructions you may
damage the press cylinder.
Note
When the press is delivered, the flow limiter is screwed in by 10
turns, which means that as soon as the press is loaded and the press
ram is first moved under pressure, the flow limiter can be screwed
out again.
Normal operation: Flow limiter (3) screwed out.
Distance A: 26 mm
Reloading / clearing: Flow limiter (3)
screwed in ten full turns.
Distance A: 11 mm
(this slows down the press and protects the press cylinder from material damage)
- Unplug the counter wheel
• The bale measuring system is now out of operation
- Turn on the main switch
• The green
“Ready”
lamp should light up
- Set the
“Operating mode”
switch depending on the material
- Press the
“Automatic On”
button
• The yellow
“Automatic mode”
lamp should light up
- Load the feeder conveyor with material -> the press starts up in automatic mode
As soon as the press is reloaded and the press ram comes up against pressure for
the first time, the flow limiter can be screwed out again.
- Switch off the baling press
- Unscrew the cap nut (1)
- Unscrew the lock nut (2)
- Using a hexagon socket spanner, unscrew the flow limiter (3)
by 10 full anticlockwise turns
- Tighten the lock nut again
- Put the cap nut back on
- Start the baling press
Summary of Contents for VK 5012
Page 16: ...6 417 999 120 Issued 06 2005 General information VK 5012 2 4 ...
Page 17: ...6 417 999 120 Issued 06 2005 VK 5012 Technical data 3 1 3 Technical data 3 1 Dimensions ...
Page 24: ...6 417 999 120 Issued 06 2005 Technical data VK 5012 3 8 ...
Page 28: ...6 417 999 120 Installation VK 5012 Issued 06 2005 4 4 ...
Page 64: ...6 417 999 120 Installation VK 5012 Issued 06 2005 5 36 ...
Page 92: ...Spare parts and accessories VK 5012 6 417 999 120 Issued 06 2005 7 2 ...
Page 94: ......
Page 95: ......
Page 96: ......