![HSM VK 5012 Operating Manual Download Page 68](http://html1.mh-extra.com/html/hsm/vk-5012/vk-5012_operating-manual_2177769068.webp)
6.417.999.120
Issued 06/2005
6.4
VK 5012
Inspection and maintenance work
Prescribed purity grade 9 according to NAS 1638 or 6 according to SAE, ASTM, AIA.
Note
Observe the environmental protection regulations when disposing of
waste oil.
Never mix hydraulic fluid and cleaning agent mixtures with waste oil
Always collect these substances in separate containers and dispose
of them according to the regulations.
Observe the applicable accident prevention regulations when
handling cleaning agents and solvents.
• With the press ram in the rear limit position
- Empty the hydraulic fluid tank -> Open the oil drain plug and catch the oil in a
collecting vessel
or completely remove the venting filter and siphon off the oil
(tank
capacity ~ 300 l )
- Blow out the venting filter with compressed air
- Check that the venting filter is not dirty or blocked
-> Replace the venting filter every 2000 operating hours
- Screw the oil drain plug back in
- Top up the oil until the float is at the top of the oil level sight glass
- Screw the venting filter back into place
Venting filter with dipstick
Part no. 6.116.195.070
6.3
Maintenance
6.3.1
Changing the hydrauli oil
Interval: 2000 operating hours or once a year
Summary of Contents for VK 5012
Page 16: ...6 417 999 120 Issued 06 2005 General information VK 5012 2 4 ...
Page 17: ...6 417 999 120 Issued 06 2005 VK 5012 Technical data 3 1 3 Technical data 3 1 Dimensions ...
Page 24: ...6 417 999 120 Issued 06 2005 Technical data VK 5012 3 8 ...
Page 28: ...6 417 999 120 Installation VK 5012 Issued 06 2005 4 4 ...
Page 64: ...6 417 999 120 Installation VK 5012 Issued 06 2005 5 36 ...
Page 92: ...Spare parts and accessories VK 5012 6 417 999 120 Issued 06 2005 7 2 ...
Page 94: ......
Page 95: ......
Page 96: ......