![HSM VK 5012 Operating Manual Download Page 62](http://html1.mh-extra.com/html/hsm/vk-5012/vk-5012_operating-manual_2177769062.webp)
6.417.999.120
Installation
VK 5012
Issued 06/2005
5.34
5.9.1
Relieving the press channel
After shearing the material is compressed and pushed into the tapered press
channel. The pressure in the press cylinder is monitored by a pressure transducer
on the control block. The opening and closing of the press channel adjustment unit
depends on the properties of the material or the pressing power.
Specialist staff can set the required values on the OP 17 operator panel.
There are two ways to relieve the conical press channel:
1.
Electronically
Press the - K 8 key in Set-up mode -> the adjustment cylinder goes down.
2.
Manually
Loosen the lock nut and unscrew the throttle screw N (= emergency drain)
by roughly one turn -> the adjustment cylinder lowers.
Note
After relieving the press channel the valve must be reset.
Basic setting: Screw in the throttle valve screw completely and then
screw it out by about 1/8 - 1/4 of a turn.